Zéro compromis et préparation absolue
The PANTHER electric
The Rosenbauer PANTHER 6×6 Electric
Maximum performance, safety, and functionality
With the revolutionary PANTHER electric, Rosenbauer is leading the current generation into the age of e-mobility. Safety and functionality from the current generation meet the advantages of electric mobility and inspire with outstanding performance and a reduction in noise and emissions – without compromise.
Le tableau de comparaison Rosenbauer ARFF
CAMIONS | The PANTHER 6x6 electric | Le PANTHÈRE 4x4 | La PANTHÈRE 6x6 | Le PANTHERE 6x6 HRET |
---|---|---|---|---|
MOTEUR | All-Electric drive with Energy Backup System | Volvo Penta D-16 Niveau 4 Industriel | Volvo Penta D-16 Niveau 4 Industriel | Volvo Penta D-16 Niveau 4 Industriel |
TRANSMISSION | High Voltage System with four electric motors powered by HV-Battery (nominal: 256 kWh) | Transmission électronique à 6 vitesses à double disque | Transmission électronique à 6 vitesses à double disque | Transmission électronique à 6 vitesses à double disque |
CAPACITÉ | 3,170 gal. water 380 gal. foam | 1585 gal. eau 200 gal. mousse | 3170 gal. eau 400 gal. mousse | 3000 gal. eau 400 gal. mousse |
POMPE | N80 2100 gpm | N80 2100 gpm | N80 2100 gpm | N80 2100 gpm |
AGENT AUXILIAIRE | 550 lbs. dry chem 460 livres. Halotron | 450-550 livres. chimie sèche 460 livres. Halotron | 450-550 livres. chimie sèche 460 livres. Halotron | 450-550 livres. chimie sèche 460 livres. Halotron |
CAPABLE D'AGENT AUXILIAIRE DE TOURELLE BUMPER | RM15 (500 gal/min) | RM15 (500 gal/min)(*) RM35 (500-1000gpm)(*) RM35 HVLA (500-1000 gpm) * = Air aspiré en option | RM15 (500 gal/min)(*) RM35 (600-1200 gal/min)(*) RM35 HVLA (600-1200 gpm) * = Air aspiré en option | RM15 (500 gal/min)(*) RM35 (600-1200 gal/min)(*) RM35 HVLA (600-1200 gpm) * = Air aspiré en option |
CAPABLE D'AGENT AUXILIAIRE DE TOURELLE DE TOIT | RM 80 (2100 gpm) | RM35 (500-1000 gal/min) Air aspiré en option | RM35 (600-1200 gal/min) Air aspiré en option | RM65 (500-1000 gal/min) |
CHARGE DE POIDS | 89,300 lbs. | 57 000 livres. | 80 000 livres. | 85 500 livres. |
ACCÉLARATION | Pure electric: 0 - 50 mph < 25 sec Combined (RIV/Boost): 0-50 mph < 20 sec | 0 - 50 mph < 25 sec | 0 - 50 mph < 35 sec | 0 - 50 mph < 35 sec |
PANTHER electric Features
Maximum Safety
The series is constantly being further developed with a focus on safety for the vehicle and its occupants. With special features such as a crash-tested cab, optimized all-round visibility, ESC, side airbags incl. seatbelt tensioners and an innovative light design, all crew members on board are guaranteed maximum safety when driving and extinguishing.
Powerful Driving Dynamics
Sporty concept: the PANTHER 6×6 accelerates from 0 to 80 km/h in up to 28 seconds. The RIV / Boost mode even allows the PANTHER electric to accelerate from 0 to 80 km/h (0-50 mph) in under 20 seconds. A low center of gravity and a chassis perfectly matched to the application also ensure outstanding driving dynamics in every situation.
High Performance
Perfectly integrated and specially developed: Powerful pumps up to 9,000 l/min normal pressure. And roof monitors with an output of up to 9,000 l/min at up to 100 m throwing distance set new standards in the industry. Even in purely electric operation, there are no limitations in firefighting performance.
Customized Energy Capacity
The number and capacity of the batteries are customized to the application of the ARFF vehicle. Typical emergency journeys can be carried out several times at top speed for 2 to 3 minutes, and correspondingly more often with lower energy consumption. The energy banks are also refilled by the high deceleration energy during the braking process through recuperation.
Uncompromised Extinguishing
Even in purely electric mode, there are no restrictions in the extinguishing performance in terms of pumping and throw ranges compared to a conventional PANTHER.
The Energy Backup System
With the integrated energy backup system, there is a fallback level on board that supplies the vehicle with additional energy by means of a diesel engine during extended journeys or training sessions. The energy backup system can provide more electrical energy in the system and the performance can be increased by boosting.
Individual Charging
From 0-100% in approx. 45 minutes: the PANTHER electric can be charged with both direct and alternating current and has a maximum charging capacity of 250 to 300 kW (DC). This means that sufficient energy can be provided in approx. 20 minutes for a typical operation that includes a high speed drive as well as discharging the extinguishing agent tank.